1. Pull strapping from cart and bring around load. Push seal
on with flat side of seal facing outside of strap. (Figure 1)
2. Slide end of strap through bottom of seal and fold over the
end to form a “hook.” (Figure 2)
3. Push the top strap through the Rack and Flapper
slot and under the Gripper Dog with
the seal against the front of the tool. Be sure the strap is
flush with the inside edge of the M1860. (Figure 3)
4. Hold the tool above package and move the Tension Lever
back and forth to tension.
5. Seal the pusher seal with an appropriate heavy-duty sealer,
according to sealer manufacturer’s instructions.
6. With seal secured, tilt the whole tool forward over the seal
and back again approximately three times to bend and
break the banding.
SAFETY WARNINGS:
• Before operating the tool, review the enclosed
Acme Safety booklet. Only trained personnel should
operate Acme hand tools.
• Only use equipment recommended for the strap. The
M1860 is recommended only for 5/8” x .025 through
1-
1/4” x .035 gauge steel.
• Dangerous breakage may occur due to excessive
tensioning, possibly resulting in severe injury or death.
Tension strap in moderation.
• Keep fingers away from areas that can pinch or cut. These
areas are primarily located at the front of the tool.
• Review the instructions and safety material on a regular
basis.
• Warning: Unsafe use may result in blindness, severe
laceration, amputation, or death.